Visual Distance Measurement
for measuring distances, detecting positions, filling level control and controlling geometric profiles
Phase-Shift-Technology
- Used in following systems: LMC-J-0040-X, LMC-J-0050-X, LMC-X-0040-X, LMC-X-0062-X for ATEX
- Measuring range from 0.1 m up to 150 m
- fmod = 800 MHz; cw-LD → 635 / 650 nm
Pulse back-mixing method
- Used in following systems: LMC-J-0510-X, LMC-J-0060-X
- Measuring range from 0.1 up to 500 m
- Measuring rates up to 100 Hz, time resolution 1ps ≈ 0.15 mm
Laser-Triangulation
- Stand Off up to 3 m
- Measuring range up to 1500 mm, accuracy up to 0.005 mm